|
Build Your Online Product Catalogs?
Product Name: |
veterinary infusion pump
|
Supply Ability: |
30 000 pieces |
Related proudcts |
infusion pump, infusion pump, infusion pump, |
Specifications |
Number of chips:2 core chips |
Price Term: |
FOB |
Port of loading: |
Changsha |
Minimum Order |
10-99 pieces |
Unit Price: |
US$ 300 |
|
Automatic Infusion Pump: High accuracy and self-correct false alarm, water-proof, anti-stick intellect design of ***ect sensor Co***tible with any brand IV set after calibration Automatic calibration for any brand IV set of any standard and automatically record the parameter Large LCD screen, intuitive, easy to operate Audible and visual bubble ***ector, accurate and safety High capacity to 8 hours internal lithium battery Auto KVO function: After liquid infusion finished, the pump automatically switch to mico-flow to prevent the thrombus Three work modes: Rate mode, Time mode, Volumetric mode Arlternative options between ml/hr and drop/ml
Application: 1. critical care of Human: ICU,CCU, Pediatrict Department, Operation room, First Aid Room,Neonate Care,etc. 2. veterinary use : Animal hospital
Technical Parameters of Medical Infusion Pump JSB-1200 Specifications Type of product JSB-1200 ***ector:outside caliper rotary ***ector (patent technology) Control way:drop counting and automatically adjust the infusion rate Co***tible IV set:co***tible with any brand IV set produced by any co***ny(include lucifugal IV set) Alarms:Air-in-line, infusion complete when volume limit has been set, empty container, occlusion, door opening, over time waiting, no drop been ***ected, error operation, low battery, device failure. Delivery rate range:1.0ml/h~1200ml/h(1.0ml/h~99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step) Delivery time range:1~1999min (1 min step) Infusion volume range:0~9999ml (1 ml step) Purge rate:600 ml/h KVO rate:when delivery rate ¡Ü10ml/h, KVO is 1 ml/h ; Otherwise KOV is 3ml/h Accuracy:¡Ü25 drop/min: ¡À2%, >25 drop/min: ¡À3% (Rate mode and Time mode), ¡À5%(Volumetric mode with correct calibration) Bolus :Bolus rate:10-200 ml/h Bolus volume: maximum of 100 ml Power Supply:AC power supply: AC 100 to 240 V +/_10%, 50/60Hz Internal lithium battery: 11.1V, 2000mAh. 8 hours of continous operation on a new fully charged battery with infusion rate of 20 drops/min |
Company: |
Epower Electronics & Science Co; Ltd.
|
Contact: |
Ms. Lisha Liu |
Address: |
Floor 9,No.199 Lulong Road, National Hi-tech |
Postcode: |
410205 |
Tel: |
86-731-84166923 |
Fax: |
86-731-84166923 |
E-mail: |
|
|
|
|